How to reconfigure WMI Settings Permissions for remote collect
1.Open Component Services
- Open the Run dialog or Command Prompt and execute:
dcomcnfg


2.Navigate to Component Services > Computers
- Right‑click My Computer and select Properties

3.Go to the COM Security tab and click Edit Limits in both sections (Access Permissions and Launch and Activation Permissions)
- Add the collection account and allow Remote Access, Remote Launch, and Remote Activation as required



4.Configure WMI DCOM permissions
- In Component Services, expand My Computer > DCOM Config
- Locate Windows Management Instrumentation, right‑click, and select Properties

- Go to the Security tab and grant the collection account Remote Launch and Remote Activation where applicable


5.Edit access permissions
- In the same Security tab, edit Access Permissions to ensure the collection account has remote access rights


6.Verify required services and groups
- Confirm that RemoteRegistry and Winmgmt (Windows Management Instrumentation) services are running and set to Startup type: Automatic
7.Add the collection account to the following local groups:
- Event Log Readers
- Distributed COM Users